"A+ Rated Merchant with No-TERM Contracts or Hidden Fees!"
Do-It-Yourself Alarm Monitoring Services - GEOARM Security®Professional Central Station Alarm Monitoring Services - GEOARM Security®Security System Coupons - GEOARM Security®$0-Down Security Equipment - GEOARM Security®Free Shipping Over $200 Dollars - GEOARM Security®How to DIY Security System Videos - GEOARM Security®How to Alarm Manuals - GEOARM Security©How to DIY Support Center - GEOARM Security®

iGSMV - Honeywell AlarmNet Dual-Paths (Broadband Internet & 2G Cellular) Alarm Communicator

iGSMV - Honeywell AlarmNet Dual-Paths (IP & 2G) Alarm Communicator (for VISTA-Series)
iGSMV - Honeywell AlarmNet Dual-Paths (IP & 2G) Alarm Communicator (for VISTA-Series)
This item is currently out of stock.

IGSMV Honeywell AlarmNet Dual Path Alarm Communicator

| More
IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Free Programming IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Free Technical Support IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Free Shipping
IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Product Description:
GeoArm is an industry leader in alternative alarm communication paths. We recognize that a traditional phone line (POTS) is no longer the only way to communicate alarm signals. With the emergence of VoIP and the huge growth in wireless networks, you can now free your security system from a POTS line and eliminate your expensive monthly phone bill.

GeoArm is proud to have partnered with Honeywell’s AlarmNet to offer a joint dual (Internet backed by cellular) alarm communication path. The IGSMV connects to compatible Honeywell alarm control panels with an easy 4-wire connection, providing an easy streamlined installation for those customers looking to have their security system monitored over the Internet instead of a traditional phone line. All that is required is a broadband internet connection plugged into the IGSMV. The internet side of the communicator is designed for true “plug-and-play” capability. No technical router setup is required.

What makes the IGSMV stand out from all other alarm communicators on the market today is its exclusive triple-path communication feature. While the internet is the most cost effective alarm communication path, it can be prone to line tampering and service outages. The cellular Global System for Mobile Communications (GSM) network on the other hand is more expensive but a much more reliable path. GSM is the dominant mobile phone system worldwide and has two different paths within one network. The IGSMV communicator uses both the primary Internet and the backup cellular GSM network to provide the most affordable and reliable communication path available. The main communication path of the IGSMV is the internet, allowing for less expensive monitoring rates; while the dual GSM technology serves as a back-up in the event the internet goes down. If the internet does go down, the IGSMV uses General Packet Radio Service (GPRS) as the secondary path and Short Messaging Service (SMS) as the tertiary path in the event that both the internet and cellular GPRS fails. By combining your broadband internet network and the cellular GSM network, the IGSMV is GeoArm’s most recommended alarm communicator

Once installed, your Ademco security system will deliver all alarm signals through the IGSMV communicator to Honeywell’s AlarmNet Network Control Center, which automatically and immediately routes the information to GeoArm's Central Station. The state of the art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery.

Remote Service Calls:
GeoArm is able to dial into your control panel’s programming to perform remote service once you have installed your IGSMV alarm communicator. GeoArm technicians can make advanced technical programming changes in minutes through your AlarmNet communicator. Never pay for an expensive house service call again.

AlarmNet Interactive Alarm Monitoring (Total Connect):
The IGSMV dual path (IP & GSM) alarm communicator not only gives you the flexibility to eliminate your phone line, it also provides you with the ability to get more out of your wireless security system. With each of the AlarmNet communicators (IP, Cellular and Dual Path), you have the option to add GeoArm's interactive alarm monitoring service (Honeywell’s Total Connect service) to your alarm monitoring plan.

With interactive alarm monitoring you will be provided with a web based log-in that will allow you to:
  • Control your alarm system with a virtual keypad
  • Arm/Disarm your system with a text message
  • Set up email notifications for up to (8) system events
  • Log onto your Total Connect account through a compatible PDA or cell phone

Total Connect - Residential Brochure
Total Connect - Commercial Brochure
Total Connect – Virtual Keypad Brochure
Total Connect - Cell Phone Compatibility
Compatible Honeywell Alarm Control Panels:
VISTA-10P (Rev.1.2 and higher)
VISTA-10PSIA (Rev.2.5 and higher)
VISTA-10SE (Rev.15 and higher)
VISTA-128B (Rev.1 and higher)
VISTA-128BP (Rev.3 and higher)
VISTA-128BPE (Rev.4.3 and higher)
VISTA-128FBP (Rev.1 and higher)
VISTA-128FBP (Rev.1 and higher)
VISTA-128SIA (Rev.3 and higher)
VISTA-128SIAE (Rev.4.3 and higher)
VISTA-15 (Rev.2 and higher)
VISTA-15P (Rev.1 and higher)
VISTA-15PSIA (Rev.3 and higher)
VISTA-20P (Rev.1 and higher)
VISTA-20PI (Rev.5 and higher)
VISTA-20PS (Rev.1 and higher)
VISTA-20PSIA (Rev.3 and higher)
VISTA-20SE (Rev.12 and higher)
VISTA-250BP (Rev.1 and higher)
VISTA-250BPE (Rev.4.3 and higher)
VISTA-250FBP (Rev.1 and higher)
VISTA-32FB (Rev.1 and higher)

IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Free Custom Programming:
Custom security system programming is FREE for all GeoArm monitored clients.

IGSMV Honeywell AlarmNet Dual Path Alarm Communicator Features:
  • Triple-Path Technology – Provides three paths of communication using Internet, GPRS, and SMS. Uses internet as primary with dual GSM technology as back-up (GSM path utilizes GPRS and automatically switches to SMS if GPRS is unavailable)
  • Secure IP Reporting - Uses 256-bit Advanced Encryption Standard or optional 1,024 bit encryption with two-way authentication and no key exchange for maximum data protection
  • Full Event Reporting – ECP full alarm reporting with all compatible Honeywell LYNX control panels
  • Full Contact ID Reporting – ECP mode with compatible Honeywell LYNX control panels supports full Contact ID reporting
  • 256-bit AES Encryption – Advanced Encryption Standard used for secure communications
  • Diagnostic LEDs – Provides signal strength and status indications
  • Tamper Protected Enclosure – Built-in tamper switch sends an alarm when the enclosure is opened
  • Built-in Power Supply – On board charging circuit design accommodates back-up battery
  • Back-Up Battery - 6V 3.1Ah battery supplied to deliver up to 24 hours of standby operation
  • Remote Downloading/Uploading – Remote GeoArm service capability through AlarmNet communicator
  • Remote Alarm Services Capability – Requires interactive monitoring plan (Total Connect)
  • Backed by Honeywell's 2-year limited manufacturer's warranty

IGSMV Honeywell AlarmNet Dual Path Alarm Communicator

Dimensions (H x W x D) 8.0 x 7.5 x 1.86 (in), 203.2 x 190.5 x 47.24 (mm)
Input Operating Voltages 10.5-14.3VDC or 9-16.5VAC (transformer included)
Backup Battery 6V, 3.1A (24hrs standby)
Operating Temperature 22° to 140°F (-30° to 60°C)
Current Requirements 60mA standby, 400mA during transmission
Transmission Power 850MHz (1 Watt) to 1900MHz (2 Watts)
Operating Relative Humidity 0% to 90% (non-condensing)
Approvals UL365 – police station connected burglar alarm units and systems
UL1610 – central station burglar alarm units
UL1635 – digital alarm communicator system units
UL985 – household fire warning system units
UL864 – control units for fire protection signaling systems
CAN/ULC–S303-M91(First Edition) – local burglar alarm units and systems
CAN/ULC–S304–M88(First Edition) – central and monitoring station for burglar alarm units
CAN/ULC Subject C1023-1974(First Edition) – household burglar alarm system units
CAN/ULC-S545-02(Second Edition) – residential fire warning system control units

IGSMV Honeywell AlarmNet Dual Path Alarm Communicator PDFs for Additional Information:
Data Sheet for Honeywell's AlarmNet IGSMV Internet/Cellular Communicator
Installation/Setup Guide for Honeywell's AlarmNet IGSMV Internet/Cellular Communicator

Honeywell Dual Communicators use your Primary GSM Path, and if down, Backup over your IP Path.
For Advanced Router Configurations, you may need to Contact your Network Administrator.
All Cellular GSM Network Fees are Included – No Overages or Third-Party Bills!

Q & A's : Honeywell iGSMV4G Dual-Path Alarm Communicator

comments powered by Disqus