Do-It-Yourself Alarm Monitoring Services - GEOARM Security®Professional Central Station Alarm Monitoring Services - GEOARM Security®Security System Coupons - GEOARM Security®$0-Down Security Equipment - GEOARM Security®Free Shipping Over $200 Dollars - GEOARM Security®How to DIY Security System Videos - GEOARM Security®How to Alarm Manuals - GEOARM Security©How to DIY Support Center - GEOARM Security®

7847i-L - Honeywell AlarmNet LYNX Broadband Internet Alarm Communicator

7847i-L - Honeywell AlarmNet Broadband Internet Alarm Communicator (for LYNX Plus L3000)
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator

| More
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Free Programming 7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Free Technical Support 7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Free Shipping
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Product Description:
GeoArm is an industry leader in alternative alarm communication paths. We recognize that a traditional phone line (PSTN) is no longer the only way to communicate alarm signals. With the emergence of VoIP and the huge growth in wireless networks, you can now free your security system from a POTS line and eliminate your expensive monthly phone bill.

GeoArm is proud to have partnered with Honeywell’s AlarmNet to offer an internet alarm communication path. The 7847i-L fits right inside the LYNX Plus wireless alarm control panel (L3000), providing an easy streamlined installation for those customers looking to have their security system monitored over the Internet instead of a traditional phone line. All that is required is a broadband Internet connection plugged into the 7847i-L. The Internet communicator is designed for true “plug-and-play” capability. No technical router setup is required.

Once installed, your LYNX wireless security system will deliver all alarm signals through the 7847i-L Internet communicator to Honeywell’s AlarmNet Network Control Center, which automatically and immediately routes the information to GeoArm's Central Station. The state of the art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery.

Remote Service Calls:
GeoArm is able to dial into your control panel’s programming to perform remote service once you have installed your 7847i-L alarm communicator. GeoArm technicians can make advanced technical programming changes in minutes through your AlarmNet communicator. Never pay for an expensive house service call again.

AlarmNet Interactive Alarm Monitoring (Total Connect):
The 7847i-L Internet communicator not only gives you the flexibility to eliminate your phone line, it also provides you with the ability to get more out of your wireless security system. With each of the AlarmNet communicators (IP, Cellular, and IP/Cellular), you have the option to add GeoArm's interactive alarm monitoring service (Honeywell’s Total Connect service) to your alarm monitoring plan.

With interactive alarm monitoring you will be provided with a web based log-in that will allow you to:
  • Control your alarm system with a virtual keypad
  • Arm/Disarm your system with a text message
  • Set up email notifications for up to (8) system events
  • Log onto your Total Connect account through a compatible PDA or cell phone


Total Connect - Residential Brochure
Total Connect - Commercial Brochure
Total Connect – Virtual Keypad Brochure
Total Connect - Cell Phone Compatibility
Compatible Honeywell LYNX Wireless Alarm Control Panels:
L3000, L3000-SIA
LYNXR-2, LYNXR-2SIA (Rev.17 and higher)
LYNXR-I, LYNXR-ISIA (Rev.17 and higher)

7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Free Custom Programming:
Custom security system programming is FREE for all GeoArm monitored clients.

7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Features:
  • Secure IP Reporting - Uses 256-bit Advanced Encryption Standard or optional 1,024 bit encryption with two-way authentication and no key exchange for maximum data protection
  • Full Event Reporting – ECP full alarm reporting with all compatible Honeywell LYNX control panels
  • Full Contact ID Reporting – ECP mode with compatible Honeywell LYNX control panels supports full Contact ID reporting
  • Network Friendly – Connects behind firewalls without compromising network security (dynamic or static IP addressing)
  • Ease of Installation – Easy Cat-5 connection to a hub or router (plug-and-play)
  • Diagnostic LEDs – Provides signal strength and status indications
  • Remote Downloading/Uploading – Remote GeoArm service capability through AlarmNet communicator
  • Remote Alarm Services Capability – Requires interactive monitoring plan (Total Connect)
  • Backed by Honeywell's 2-year limited manufacturer's warranty


Chart of the 7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator

Specifications
Dimensions (H x W) 2.24 x 2.125 (in), 56.90 x 53.97 (mm)
Installs inside the LYNXR-2 alarm control panel
Network Standard IEEE 802.3u compliant
Data Rate 10Base-T/100Base-T with auto detect
Ethernet Cable Cat.5 (min.), MDI/MDI-X auto crossover
Input Operating Voltages 12VDC (nominal), 14VDC (max)
Current Drain 56mA
Shutdown Voltage 5.5VDC
Operating Temperature -4° to 131°F (-20° to 55°C)
Operating Relative Humidity 0% to 95% (non-condensing)
Approvals UL – residential/commercial
CUL – residential/commercial burglary
UL1023 – standard for household burglar alarm system units
UL609 – standard for local burglar alarm units and systems
UL365 – police station connected burglar alarm units and systems
UL1610 – central station burglar alarm units
UL1635 – digital alarm communicator system units
UL985 – household fire warning system units
UL864 – control units for fire protection signaling systems
CAN/ULC–S303-M91(First Edition) – local burglar alarm units and systems
CAN/ULC–S304–M88(First Edition) – central and monitoring station for burglar alarm units
ULC Subject C1023-1974 – preliminary standard for household burglar alarm system units



Q & A's : Honeywell 7847i-L Internet Alarm Communicator (for L3000)



comments powered by Disqus