Add the 7847i-L to Honeywell's LYNX Plus Wireless Security System and eliminate the need for a phone line. Send your alarm signals over the Internet and give your security system the ability to upgrade to Interactive Alarm Monitoring.
Honeywell IP Communicators are designed to work plug-and-play with a Broadband IP Connection.
For Advanced Router Configurations, you may need to Contact your Network Administrator.
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Product Description:
GeoArm is an industry leader in alternative alarm communication paths. We recognize that a traditional phone line (PSTN) is no longer the only way to communicate alarm signals. With the emergence of VoIP and the huge growth in wireless networks, you can now free your security system from a POTS line and eliminate your expensive monthly phone bill.
GeoArm is proud to have partnered with Honeywell’s AlarmNet to offer an internet alarm communication path. The 7847i-L fits right inside the
LYNX Plus wireless alarm control panel (L3000), providing an easy streamlined installation for those customers looking to have their security system monitored over the Internet instead of a traditional phone line. All that is required is a broadband Internet connection plugged into the 7847i-L. The Internet communicator is designed for true “plug-and-play” capability. No technical router setup is required.
Once installed, your LYNX wireless security system will deliver all alarm signals through the 7847i-L Internet communicator to Honeywell’s AlarmNet Network Control Center, which automatically and immediately routes the information to GeoArm's Central Station. The state of the art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery.
Remote Service Calls:
GeoArm is able to dial into your control panel’s programming to perform remote service once you have installed your 7847i-L alarm communicator. GeoArm technicians can make advanced technical programming changes in minutes through your AlarmNet communicator. Never pay for an expensive house service call again.
AlarmNet Interactive Alarm Monitoring (Total Connect):
The 7847i-L Internet communicator not only gives you the flexibility to eliminate your phone line, it also provides you with the ability to get more out of your wireless security system. With each of the AlarmNet communicators (IP, Cellular, and IP/Cellular), you have the option to add GeoArm's
interactive alarm monitoring service (Honeywell’s Total Connect service) to your alarm monitoring plan.
With interactive alarm monitoring you will be provided with a web based log-in that will allow you to:
- Control your alarm system with a virtual keypad
- Arm/Disarm your system with a text message
- Set up email notifications for up to (8) system events
- Log onto your Total Connect account through a compatible PDA or cell phone
Total Connect - Residential Brochure
Total Connect - Commercial Brochure
Total Connect – Virtual Keypad Brochure
Total Connect - Cell Phone CompatibilityAlarmNet Total Connect Demo Videos:
Total Connect Services - Residential
Total Connect Services - CommercialCompatible Honeywell LYNX Wireless Alarm Control Panels:
L3000, L3000-SIA
LYNXR-2, LYNXR-2SIA (Rev.17 and higher)
LYNXR-I, LYNXR-ISIA (Rev.17 and higher)
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Free Custom Programming:
Custom security system programming is FREE for all GeoArm monitored clients.
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator Features:
- Secure IP Reporting - Uses 256-bit Advanced Encryption Standard or optional 1,024 bit encryption with two-way authentication and no key exchange for maximum data protection
- Full Event Reporting – ECP full alarm reporting with all compatible Honeywell LYNX control panels
- Full Contact ID Reporting – ECP mode with compatible Honeywell LYNX control panels supports full Contact ID reporting
- Network Friendly – Connects behind firewalls without compromising network security (dynamic or static IP addressing)
- Ease of Installation – Easy Cat-5 connection to a hub or router (plug-and-play)
- Diagnostic LEDs – Provides signal strength and status indications
- Remote Downloading/Uploading – Remote GeoArm service capability through AlarmNet communicator
- Remote Alarm Services Capability – Requires interactive monitoring plan (Total Connect)
- Backed by Honeywell's 2-year limited manufacturer's warranty
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator
| Specifications |
| Dimensions (H x W) |
2.24 x 2.125 (in), 56.90 x 53.97 (mm) Installs inside the LYNXR-2 alarm control panel |
| Network Standard |
IEEE 802.3u compliant |
| Data Rate |
10Base-T/100Base-T with auto detect |
| Ethernet Cable |
Cat.5 (min.), MDI/MDI-X auto crossover |
| Input Operating Voltages |
12VDC (nominal), 14VDC (max) |
| Current Drain |
56mA |
| Shutdown Voltage |
5.5VDC |
| Operating Temperature |
-4° to 131°F (-20° to 55°C) |
| Operating Relative Humidity |
0% to 95% (non-condensing) |
| Approvals |
UL – residential/commercial CUL – residential/commercial burglary UL1023 – standard for household burglar alarm system units UL609 – standard for local burglar alarm units and systems UL365 – police station connected burglar alarm units and systems UL1610 – central station burglar alarm units UL1635 – digital alarm communicator system units UL985 – household fire warning system units UL864 – control units for fire protection signaling systems CAN/ULC–S303-M91(First Edition) – local burglar alarm units and systems CAN/ULC–S304–M88(First Edition) – central and monitoring station for burglar alarm units ULC Subject C1023-1974 – preliminary standard for household burglar alarm system units |
7847i-L Honeywell AlarmNet LYNX Internet Alarm Communicator PDFs for Additional Information:
Data Sheet for Honeywell's AlarmNet 7847i-L IP Communicator
Installation/Setup Guide for Honeywell's AlarmNet 7847i-L IP Communicator | Do-It-Yourself with GeoArm
Save Your Money, Property and Life Today! |  |